Repair methods and preventive measures for vulcanization of lead-acid battery plates
2022 Jul 23 By admin 0 comment

The repair of the vulcanization failure of the battery plate is to find a way to soften, refine and dissolve the white and hard dendritic sulfate crystals on the plate, enhance the original reversible chemical reaction ability of the active material of the plate, and restore it to a good state. performance. The sulfate crystals generated by the vulcanization of the plates are generally difficult to be electrolytically reduced to lead if charged with conventional chargers. For plate vulcanization failure, the following methods are usually used for flexible repair. (For more battery repair knowledge visit Tycorun Battery) Several repair methods…

What are the reasons for the vulcanization of lead-acid battery plates?
2022 Jul 14 By admin 0 comment

The reason for the vulcanization failure of the pole plate (1) The initial charging is insufficient or the initial charging is interrupted.(2) After the battery is discharged, if it is not charged in time or is often insufficiently charged within 24 hours, and the idle battery lacks due regular charging, a part of lead sulfate that has not been decomposed and reduced will remain on the electrode plate, which will be converted into sulfate over time, so that the Plate vulcanization.(3) The battery is often discharged with high current and overdischarged, and it is in deep discharge with low current…

Explain in detail the detection method and specific application of lead-acid battery
2022 Jun 20 By admin 0 comment

Parameter testing method of lead-acid battery 1.1 Several methods for judging the sufficient charge of lead-acid batteriesDuring the charging process of the battery, the voltage will gradually increase. Especially when the battery is fully charged, the following characteristic features are often exhibited. According to these characteristics, it can be judged that the battery is fully charged. (1) When the battery is charged, the electrolyte produces a large number of bubbles and forms a boiling state.(2) When the battery is charging, use a multimeter to measure the voltage of each single cell to 2.4V-2.5v.(3) When the battery is charging, the measured…

Supplementary power, normal discharge technology of lead-acid battery and the harm of overcharge and discharge to the battery
2022 Jun 14 By admin 0 comment

Lead-acid battery supplementary technology 1.1 Requirements for chargers for lead-acid battery supplementary powerThe charged new battery should be replenished in time after being stored for half a year or before the initial use, and after the battery in use is discharged.A special charger should be used for supplementary power, which should meet the following requirements.(1) The charger should have constant voltage control function. The charger output constant voltage distributed to each single battery should be 2.5V or comply with the manufacturer’s regulations.(2) The charger should have high current output capability. Because the current of the battery in the initial stage…

Balance charging technology and fast charging technology of lead-acid battery
2022 Jun 06 By admin 0 comment

Lead-acid battery equalization charging technology 1.1 When equalizing charging is requiredIn the process of repeated charging and discharging of lead-acid batteries, even if the conventional charging method is used for charging, the single cells in the battery are often unbalanced for some reason. For example, the proportion of materials used in the manufacturing process of the electrode plates is inconsistent, impurities are mixed in the electrolyte, and there is a slight short circuit inside individual cells, etc., which may cause sulfation of a single cell, reducing the density and capacity of the electrolyte. , which also causes the imbalance of…

Lead-acid battery-conventional charging technology and floating charging technology
2022 May 25 By admin 0 comment

Lead-acid battery conventional charging technology 1.1. Characteristics and requirements of conventional chargingConventional charging, also known as regular charging or frequent charging, is a work that is often done in the use and maintenance of batteries. It is different from the requirements for the initial charge of a new battery. When the lead-acid battery is used until the single cell voltage drops to 1.8V, it should be charged in time. When the battery is not used after being charged, it should also be routinely charged once a month to make up for the power loss caused by its self-discharge.When the lead-acid…

Batteries – How much do you know about the model naming and electrolyte preparation technology of lead batteries?
2022 Apr 20 By admin 0 comment

Model designation of lead-acid battery 1.1. Traditional nomenclature of lead-acid battery models The model designation of lead-acid battery is often composed of three characters. The first part uses numbers to indicate the number of single cells in series. If it is a single cell, this part is often not marked; The second part uses 1-3 letters to indicate the purpose, type and material of lead-acid battery in turn; the third part uses numbers to indicate the rated capacity of battery. The marking method of its model is as follows. 1) Standard marking method of lead-acid battery model For example, the…